Catheter for Cleaning Surgical Optics During Surgical Procedures: Possible Solution for Residue Buildup and Fogging in Video Surgery

Abstract:

Currently, there is a tendency to perform surgical procedures via laparoscopic or thoracoscopic access. However, even with the impressive technological advancement in surgical materials, such as improvement in quality of monitors, light sources, and optical fibers, surgeons have to face simple problems that can greatly hinder surgery by video. One is the formation of “fog” or residue buildup on the lens, causing decreased visibility. Intracavitary techniques for cleaning surgical optics and preventing fog formation have been described; however, some of these techniques employ the use of expensive and complex devices designed solely for this purpose. Moreover, these techniques allow the cleaning of surgical optics when they becomes dirty, which does not prevent the accumulation of residue in the optics. To solve this problem we have designed a device that allows cleaning the optics with no surgical stops and prevents the fogging and residue accumulation. The objective of this study is to evaluate through experimental testing the effectiveness of a simple device that prevents the accumulation of residue and fogging of optics used in surgical procedures performed through thoracoscopic or laparoscopic access. Ex-vivo experiments were performed simulating the conditions of residue presence in surgical optics during a video surgery. The experiment consists in immersing the optics and catheter set connected to the IV line with crystalloid solution in three types of materials: blood, blood plus fat solution, and 200 mL of distilled water and 1 vial of methylene blue. The optics coupled to the device were immersed in 200 mL of each type of residue, repeating each immersion 10 times for each distinct residue for both thirty and zero degrees optics, totaling 420 experiments. A success rate of 98.1% was observed after the experiments, in these cases the device was able to clean and prevent the residue accumulation in the optics.

Authors:

Igor Renato Louro Bruno de Abreu, MD, Thoracic Surgeon, Hospital Santa Marcelina Itaquera, São Paulo, Brazil, Fernando Conrado Abrão, MD, Thoracic Surgeon, Hospital Santa Marcelina Itaquera, São Paulo, Brazil, Alessandra Rodrigues Silva, Medical Student, Faculdade Santa Marcelina, São Paulo, Brazil, Larissa Teresa Cirera Corrêa, Medical Student, Faculdade Santa Marcelina, São Paulo, Brazil, Riad Nain Younes, MD, Professor and Thoracic Surgeon, Hospital São José, São Paulo, Brazil

Buy and download instantly for only $77.00

$77.00
Order Article Copies 

For Direct IP Access please click this link